Category OBD Codes

Toyota Starlet 1990-1996 OBD DIY Diagnostic Tutorial – No OBD Tool needed

Switch ignition OFF.
Bridge data link connector (DLC) terminals E1 and TE2 Fig. 2 . Switch ignition ON.
Ensure malfunction indicator lamp (MIL) flashes four times per second. Start engine.

Post Content

Toyota Starlet 1990-1996 OBD DIY Diagnostic Tutorial – No OBD Tool needed

GENERAL INFORMATION:

1.Trouble codes are displayed by the malfunction indicator lamp (MIL).
2.Late models: The ECM fault memory can also be checked using diagnostic equipment connected to the data link connector (DLC).

ACCESSING:

Normal mode

1.)Switch ignition ON.

2.)Bridge data link connector (DLC) terminals E1 and TE1. SOHC: Fig. 1

TOYOTA STarlet jumper wire

3.)If no trouble codes are stored, the lamp will flash twice per second Fig. 3 .

TOYOTA STarlet jumper wires setting obd 1 codes

4.)Each trouble code consists of two groups of one or more flashes Fig. 4 [A].

TOYOTA STarlet jumper wires setting obd 1 codes separate

5.)Warning lamp flash duration: 0,5 second Fig. 4 [B].

TOYOTA STarlet jumper wires setting obd 1 codes separate

6.)A 0,5 second pause separates each flash Fig. 4 [C].

TOYOTA STarlet jumper wires setting obd 1 codes separate

7.)A 1,5 second pause separates each trouble code group Fig. 4 [D].

TOYOTA STarlet jumper wires setting obd 1 codes separate

8.)A 2,5 second pause separates each trouble code Fig. 4 [E].

TOYOTA STarlet jumper wires setting obd 1 codes separate

9.)For example: Two 0,5 second flashes – 1,5 second pause – one 0,5 second flash.

10.)Trouble code 21 displayed Fig. 4 -oxygen sensor (O2S)/heated oxygen sensor (HO2S).

TOYOTA STarlet jumper wires setting obd 1 codes separate

11.)Trouble codes are repeated 4,5 seconds after last trouble code.

12.Count MIL flashes. Note trouble codes. Compare with trouble code table.

mil light obd 1

13.)Remove bridge wire.
14.)Switch ignition OFF.
15.)Rectify faults as necessary.

Test mode – DOHC

1.)Switch ignition OFF.
2.)Bridge data link connector (DLC) terminals E1 and TE2 Fig. 2 .

TOYOTA STarlet jumper wires setting

3.)Switch ignition ON.
4.)Ensure malfunction indicator lamp (MIL) flashes four times per second.
5.)Start engine.
6.)Drive vehicle at over 6 mph (10 km/h).
7.)Stop vehicle.
8.)Do not switch ignition OFF.
9.)With data link connector (DLC) terminals E1 and TE2 bridged, bridge terminals E1 and TE1 Fig. 2 .

TOYOTA STarlet jumper wires setting

10.)Count MIL flashes. Note trouble codes. Compare with trouble code table.

mil light obd 1

11.)Switch ignition OFF.
11.)Remove bridge wires.

12.Rectify faults as necessary.

NOTE: Codes 42 and 43 may be produced if this procedure is NOT carried out correctly. Code 51 will be produced during this procedure and can be ignored.

Erasing

NOTE: Fuse removal duration depends on ambient temperature. The lower the temperature the longer the fuse must be removed.

1.)Switch ignition OFF.
2.)Remove EFI fuse (15A) from underbonnet fusebox for 10 seconds minimum.
SOHC: Location Fig. 5 [1] & Fig. 5 [2].

TOYOTA STarlet jumper wire fuse location

DOHC: Location Fig. 6 [3] & Fig. 6 [4].

TOYOTA STarlet jumper wire fuse location FIG 6

3.)Refit fuse.

Trouble codes may also be erased by disconnecting battery leads.

WARNING: Disconnecting the battery may erase memory from electronic units (e.g. radio, clock).

Repeat checking procedure to ensure no data remains in ECM fault memory.

Flash type Fault location Probable cause
11111 No fault found
12 Crankshaft position (CKP) sensor/engine speed (RPM) sensor – no signal Wiring, CKP/RPM sensor, ignition amplifier, ECM
13 Crankshaft position (CKP) sensor/engine speed (RPM) sensor – no signal over 1500 rpm Wiring, CKP/RPM sensor, ECM
14 Ignition signal – no signal Wiring, ignition amplifier, ignition coil, ECM
21 2E-E: Oxygen sensor (O2S) Wiring, O2S, ECM
21 4E-FE: Heated oxygen sensor (HO2S) Wiring, HO2S, ECM
22 Engine coolant temperature (ECT) sensor – open/short circuit Wiring, ECT sensor, ECM
24 Intake air temperature (IAT) sensor – open/short circuit Wiring, IAT sensor, ECM
25 Weak mixture Wiring, injector, O2S/HO2S, ECM, fuel pressure, air leak, MAP sensor, ignition system
26 Rich mixture Wiring, injector, fuel pressure, MAP sensor, cold start injector, ECM
31 Manifold absolute pressure (MAP) sensor Wiring, MAP sensor, ECM
33 Idle air control (IAC) valve Wiring, IAC valve, ECM
41 Throttle position (TP) sensor Wiring, TP sensor, ECM
42 Vehicle speed sensor (VSS) Wiring, VSS, ECM
43 Starter signal Wiring, ignition switch, ECM
51 Switch signal – AC switch ON during diagnosis Wiring, AC switch, AC control module, ECM
51 Switch signal – PNP switch not in P or N during diagnosis Wiring, PNP switch, ECM
Switch signal – throttle position (TP) sensor, NO closed throttle signal during diagnosis Wiring, TP sensor, ECM

Toyota Startlet 1996-1999 Obd1-Diy Diagnostic Tutorial

toyota startlet obd 1 codes diagnostic guide

Post Content

Toyota Startlet 1996-1999 Obd1-Diy Diagnostic Tutorial

 

General information
Trouble codes are displayed by the malfunction indicator lamp (MIL).
Late models: The ECM fault memory can also be checked using diagnostic equipment connected to the data link connector (DLC).

Accessing

Normal mode
1 Switch ignition ON.
2 Bridge data link connector (DLC) terminals E1 and TE1. SOHC: Fig. 1 . DOHC: Fig. 2 . If no trouble codes are stored, the lamp will flash twice per second Fig. 3 .
3 Each trouble code consists of two groups of one or more flashes Fig. 4 [A]. Warning lamp flash duration: 0,5 second Fig. 4 [B].
4 A 0,5 second pause separates each flash Fig. 4 [C].
5 A 1,5 second pause separates each trouble code group Fig. 4 [D]. A 2,5 second pause separates each trouble code Fig. 4 [E].
6 For example: Two 0,5 second flashes – 1,5 second pause – one 0,5 second flash. Trouble code 21 displayed Fig. 4 – oxygen sensor (O2S)/heated oxygen sensor (HO2S).
7 Trouble codes are repeated 4,5 seconds after last trouble code.
9 Count MIL flashes. Note trouble codes. Compare with trouble code table. Remove bridge wire.
10 Switch ignition OFF. Rectify faults as necessary.

Test mode – DOHC
1 Switch ignition OFF.
2 Bridge data link connector (DLC) terminals E1 and TE2 Fig. 2 . Switch ignition ON.
3 Ensure malfunction indicator lamp (MIL) flashes four times per second. Start engine.
4 Drive vehicle at over 6 mph (10 km/h). Stop vehicle. Do not switch ignition OFF.
5 With data link connector (DLC) terminals E1 and TE2 bridged, bridge terminals E1 and TE1 Fig. 2 . Count MIL flashes. Note trouble codes. Compare with trouble code table.
6 Switch ignition OFF. Remove bridge wires. Rectify faults as necessary.

toyota startlet obd 1 codes diagnostic guide

toyota startlet obd 1 codes